Exit Code: 0x00</nowiki> | Exit Code: 0x00</nowiki> | ||
One of the 300GB SAS drives (for the OS) is reporting a [https://techterms.com/definition/smart SMART] error. This disk should be replaced before it fails. | One of the 300GB SAS drives (for the OS) is reporting a [https://techterms.com/definition/smart SMART] error. This disk should be replaced before it fails. | ||
=== Disk swap === | |||
This is where the disk is swapped over. Once the new disk is inserted it rebuilds itself. | |||
<nowiki># megacli -pdoffline -physdrv[32:5] -a0 | |||
Adapter: 0: EnclId-32 SlotId-5 state changed to OffLine. | |||
Exit Code: 0x00 | |||
# megacli -pdmarkmissing -physdrv[32:5] -a0 | |||
EnclId-32 SlotId-5 is marked Missing. | |||
Exit Code: 0x00 | |||
# megacli -pdprprmv -physdrv[32:5] -a0 | |||
Prepare for removal Success | |||
Exit Code: 0x00 | |||
# megacli -PDRbld -ShowProg -PhysDrv[32:5] -a0 | |||
Rebuild Progress on Device at Enclosure 32, Slot 5 Completed 7% in 8 Minutes. | |||
</nowiki> |
Revision as of 20:52, 24 February 2024
These adapters are called Percraid on Dell Poweredge servers. Uses the MegaCLI utility.
MegaCLI
This to show what virtual disks are present. This describes a system with a pair of 300GB SAS 15k rpm disks holding the OS, an array of four 1TB drives and a pair modern 20TB drives, forming a 300GB OS drive, a 20TB data drive and a 3TB additional storage drive. Below are the virtual drives:
# megacli -LDInfo -Lall -a0 Adapter 0 -- Virtual Drive Information: Virtual Drive: 0 (Target Id: 0) Name :OS-Disk RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0 Size : 278.875 GB Sector Size : 512 Mirror Data : 278.875 GB State : Optimal Strip Size : 64 KB Number Of Drives : 2 Span Depth : 1 Default Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy : Disk's Default Encryption Type : None Default Power Savings Policy: Controller Defined Current Power Savings Policy: None Can spin up in 1 minute: Yes LD has drives that support T10 power conditions: Yes LD's IO profile supports MAX power savings with cached writes: No Bad Blocks Exist: Yes Is VD Cached: No Virtual Drive: 1 (Target Id: 1) Name :spare-r5 RAID Level : Primary-5, Secondary-0, RAID Level Qualifier-3 Size : 2.727 TB Sector Size : 512 Parity Size : 931.0 GB State : Optimal Strip Size : 64 KB Number Of Drives : 4 Span Depth : 1 Default Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy : Disk's Default Ongoing Progresses: Background Initialization: Completed 41%, Taken 933 min. Encryption Type : None Default Power Savings Policy: Controller Defined Current Power Savings Policy: None Can spin up in 1 minute: Yes LD has drives that support T10 power conditions: No LD's IO profile supports MAX power savings with cached writes: No Bad Blocks Exist: No Is VD Cached: No Virtual Drive: 2 (Target Id: 2) Name : RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0 Size : 18.189 TB Sector Size : 512 Mirror Data : 18.189 TB State : Optimal Strip Size : 64 KB Number Of Drives : 2 Span Depth : 1 Default Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy : Disk's Default Ongoing Progresses: Background Initialization: Completed 4%, Taken 933 min. Encryption Type : None Default Power Savings Policy: Controller Defined Current Power Savings Policy: None Can spin up in 1 minute: Yes LD has drives that support T10 power conditions: No LD's IO profile supports MAX power savings with cached writes: No Bad Blocks Exist: No Is VD Cached: No Exit Code: 0x00
And here are the physical drives. All eight drive bays are filled.
# megacli -pdlist -a0 Adapter #0 Enclosure Device ID: 32 Slot Number: 0 Drive's position: DiskGroup: 1, Span: 0, Arm: 0 Enclosure position: 1 Device Id: 0 WWN: 50014ee057c5c7cd Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 931.512 GB [0x74706db0 Sectors] Non Coerced Size: 931.012 GB [0x74606db0 Sectors] Coerced Size: 931.0 GB [0x74600000 Sectors] Sector Size: 0 Firmware state: Online, Spun Up Device Firmware Level: 0C12 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x4433221107000000 Connected Port Number: 7(path0) Inquiry Data: WD-WMATV8663060WDC WD1002FBYS-18W8B1 03.00C12 FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 3.0Gb/s Link Speed: 3.0Gb/s Media Type: Hard Disk Device Drive Temperature :43C (109.40 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's NCQ setting : N/A Port-0 : Port status: Active Port's Linkspeed: 3.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 32 Slot Number: 1 Drive's position: DiskGroup: 1, Span: 0, Arm: 1 Enclosure position: 1 Device Id: 1 WWN: 50014ee057c5c5f4 Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 931.512 GB [0x74706db0 Sectors] Non Coerced Size: 931.012 GB [0x74606db0 Sectors] Coerced Size: 931.0 GB [0x74600000 Sectors] Sector Size: 0 Firmware state: Online, Spun Up Device Firmware Level: 0C12 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x4433221106000000 Connected Port Number: 6(path0) Inquiry Data: WD-WMATV8635175WDC WD1002FBYS-18W8B1 03.00C12 FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 3.0Gb/s Link Speed: 3.0Gb/s Media Type: Hard Disk Device Drive Temperature :47C (116.60 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's NCQ setting : N/A Port-0 : Port status: Active Port's Linkspeed: 3.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 32 Slot Number: 2 Drive's position: DiskGroup: 1, Span: 0, Arm: 2 Enclosure position: 1 Device Id: 2 WWN: 50014ee206916984 Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 931.512 GB [0x74706db0 Sectors] Non Coerced Size: 931.012 GB [0x74606db0 Sectors] Coerced Size: 931.0 GB [0x74600000 Sectors] Sector Size: 0 Firmware state: Online, Spun Up Device Firmware Level: 1V02 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x4433221105000000 Connected Port Number: 1(path0) Inquiry Data: WD-WMAW30234603WDC WD1003FBYX-18Y7B0 01.01V02 FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 3.0Gb/s Link Speed: 3.0Gb/s Media Type: Hard Disk Device Drive Temperature :44C (111.20 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's NCQ setting : N/A Port-0 : Port status: Active Port's Linkspeed: 3.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 32 Slot Number: 3 Drive's position: DiskGroup: 1, Span: 0, Arm: 3 Enclosure position: 1 Device Id: 3 WWN: 50014ee057c5c89b Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 931.512 GB [0x74706db0 Sectors] Non Coerced Size: 931.012 GB [0x74606db0 Sectors] Coerced Size: 931.0 GB [0x74600000 Sectors] Sector Size: 0 Firmware state: Online, Spun Up Device Firmware Level: 0C12 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x4433221104000000 Connected Port Number: 2(path0) Inquiry Data: WD-WMATV8637476WDC WD1002FBYS-18W8B1 03.00C12 FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 3.0Gb/s Link Speed: 3.0Gb/s Media Type: Hard Disk Device Drive Temperature :44C (111.20 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's NCQ setting : N/A Port-0 : Port status: Active Port's Linkspeed: 3.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 32 Slot Number: 4 Drive's position: DiskGroup: 0, Span: 0, Arm: 1 Enclosure position: 1 Device Id: 4 WWN: 5000C50072369C50 Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS Raw Size: 279.396 GB [0x22ecb25c Sectors] Non Coerced Size: 278.896 GB [0x22dcb25c Sectors] Coerced Size: 278.875 GB [0x22dc0000 Sectors] Sector Size: 0 Firmware state: Online, Spun Up Device Firmware Level: YSFA Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5000c50072369c51 SAS Address(1): 0x0 Connected Port Number: 4(path0) Inquiry Data: SEAGATE ST9300453SS YSFA6XN69MSN FDE Capable: Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :37C (98.60 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Port-1 : Port status: Active Port's Linkspeed: Unknown Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 32 Slot Number: 5 Drive's position: DiskGroup: 0, Span: 0, Arm: 0 Enclosure position: 1 Device Id: 5 WWN: 5000C50070D8CDEC Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 1 Last Predictive Failure Event Seq Number: 4812 PD Type: SAS Raw Size: 279.396 GB [0x22ecb25c Sectors] Non Coerced Size: 278.896 GB [0x22dcb25c Sectors] Coerced Size: 278.875 GB [0x22dc0000 Sectors] Sector Size: 0 Firmware state: Online, Spun Up Device Firmware Level: ES66 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5000c50070d8cded SAS Address(1): 0x0 Connected Port Number: 3(path0) Inquiry Data: SEAGATE ST3300657SS ES666SJ7P3BJ FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :42C (107.60 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Port-1 : Port status: Active Port's Linkspeed: Unknown Drive has flagged a S.M.A.R.T alert : Yes Enclosure Device ID: 32 Slot Number: 6 Drive's position: DiskGroup: 2, Span: 0, Arm: 0 Enclosure position: 1 Device Id: 6 WWN: 5000c500e5e26a83 Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 18.190 TB [0x918600000 Sectors] Non Coerced Size: 18.189 TB [0x918500000 Sectors] Coerced Size: 18.189 TB [0x918500000 Sectors] Sector Size: 0 Firmware state: Online, Spun Up Device Firmware Level: EN01 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x4433221101000000 Connected Port Number: 5(path0) Inquiry Data: ZVT3DWS4ST20000NE000-3G5101 EN01 FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive: Not Certified Drive Temperature :38C (100.40 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's NCQ setting : N/A Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 32 Slot Number: 7 Drive's position: DiskGroup: 2, Span: 0, Arm: 1 Enclosure position: 1 Device Id: 7 WWN: 5000c500e5e0b4b9 Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 18.190 TB [0x918600000 Sectors] Non Coerced Size: 18.189 TB [0x918500000 Sectors] Coerced Size: 18.189 TB [0x918500000 Sectors] Sector Size: 0 Firmware state: Online, Spun Up Device Firmware Level: EN01 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x4433221100000000 Connected Port Number: 0(path0) Inquiry Data: ZVT4F6DGST20000NE000-3G5101 EN01 FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive: Not Certified Drive Temperature :36C (96.80 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's NCQ setting : N/A Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Exit Code: 0x00
One of the 300GB SAS drives (for the OS) is reporting a SMART error. This disk should be replaced before it fails.
Disk swap
This is where the disk is swapped over. Once the new disk is inserted it rebuilds itself.
# megacli -pdoffline -physdrv[32:5] -a0 Adapter: 0: EnclId-32 SlotId-5 state changed to OffLine. Exit Code: 0x00 # megacli -pdmarkmissing -physdrv[32:5] -a0 EnclId-32 SlotId-5 is marked Missing. Exit Code: 0x00 # megacli -pdprprmv -physdrv[32:5] -a0 Prepare for removal Success Exit Code: 0x00 # megacli -PDRbld -ShowProg -PhysDrv[32:5] -a0 Rebuild Progress on Device at Enclosure 32, Slot 5 Completed 7% in 8 Minutes.